TJEH / CVE reading sheet
CVE-2026-133662
The available vulnerability information, collected from NVD and presented by TJEH.
View the official NVD record (new tab)Highest published CVSS score
8.4 / 10
Scores may come from the assigning authority or NIST and can change.
- Published
- 20 Nov 2026, 12:18
- NVD update
- 24 Nov 2026, 16:22
- Last collected by TJEH
- 24 Nov 2026, 18:32
Times shown in Paris time.
In plain language
Raw watch record
This record has not yet been explained by TJEH. It shows the source information as published.
A missing authorization check may expose a restricted action.
General explanation of the reported weakness type (CWE), not an analysis of this specific CVE.
What the source reports
Source description as published by NVD
flowintel contains multiple authorization bypass vulnerabilities in its Analyzer (MISP Modules) functionality, affecting both the web interface and the REST API. - Saving analyzer results to a case or task accepted caller-supplied case and task identifiers without verifying that the authenticated user is a member of the target case or holds the required restricted-task permissions. An authenticated user could write notes, create tasks, and attach MISP objects or attributes into another organization's case. - Stored analyzer results were retrievable by UUID by any authenticated user. Both the web endpoint and the API endpoint returned the full result payload without checking ownership, exposing another user's analysis output. - The save handler did not validate the structure of the request, did not reject conflicting destination selections, and did not halt processing when a task-note operation failed, allowing partial or unintended writes. Preconditions: the attacker must possess a valid authenticated session (or API token) in flowintel. No administrative role is required. Security impact: unauthorized cross-tenant data disclosure (analyzer results) and unauthorized cross-tenant data modification (notes, tasks, MISP objects/attributes in another organization's case). Affected versions: flowintel prior to 4.1.0.
Fix and what to do
No verified fix here yet
Check whether your product and version are affected, then follow the publisher’s advisory to update. A published fix does not mean it has been installed on your systems.
Published CVSS metrics
CVSS 4.0 · 8.4/10
5a6e4751-2f3f-4070-9419-94fb35b644e8
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:H/SI:H/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Reported weaknesses : CWE-639 · CWE-862