TJEH / CVE reading sheet
CVE-2026-133841
The available vulnerability information, collected from NVD and presented by TJEH.
View the official NVD record (new tab)Highest published CVSS score
5.3 / 10
Scores may come from the assigning authority or NIST and can change.
- Published
- 20 Nov 2026, 16:17
- NVD update
- 20 Nov 2026, 18:18
- Last collected by TJEH
- 20 Nov 2026, 20:28
Times shown in Paris time.
In plain language
Raw watch record
This record has not yet been explained by TJEH. It shows the source information as published.
A missing authorization check may expose a restricted action.
General explanation of the reported weakness type (CWE), not an analysis of this specific CVE.
What the source reports
Source description as published by NVD
FlowIntel contains an authorization bypass in its case serialization logic that allows an authenticated user to view metadata of private cases they do not have access to. When a case is linked to another case, the JSON representation of the source case included the ID, title, and description of every linked case regardless of the requesting user's permissions. This affected multiple access paths: - Browser views (case detail, case info, search, calendar) - REST API endpoints (get case, list cases, search, title lookup, completed/not-completed lists) - Internal tooling and connector module context building An attacker with valid credentials and access to any case that contains a link to a private case could enumerate the private case's identifier, title, and description without holding a membership or role on that private case. The exposure occurred because the serialization method did not receive or evaluate the acting user's identity before including linked-case data in the response. Security impact: - Disclosure of private case identifiers, titles, and descriptions to unauthorized users - Facilitation of further targeted attacks against the exposed private cases - Bypass of the intended per-case access control model Affected versions: FlowIntel prior to 4.1.0
Fix and what to do
No verified fix here yet
Check whether your product and version are affected, then follow the publisher’s advisory to update. A published fix does not mean it has been installed on your systems.
Published CVSS metrics
CVSS 4.0 · 5.3/10
5a6e4751-2f3f-4070-9419-94fb35b644e8
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Reported weaknesses : CWE-200 · CWE-862