TJEH / CVE reading sheet
CVE-2026-91007
The available vulnerability information, collected from NVD and presented by TJEH.
View the official NVD record (new tab)Highest published CVSS score
7.8 / 10
Scores may come from the assigning authority or NIST and can change.
- Published
- 12 Nov 2026, 17:19
- NVD update
- 17 Nov 2026, 18:18
- Last collected by TJEH
- 17 Nov 2026, 20:28
Times shown in Paris time.
In plain language
Raw watch record
This record has not yet been explained by TJEH. It shows the source information as published.
What the source reports
Source description as published by NVD
The user-mode syscall verifiers for the charger driver API in drivers/charger/charger_handlers.c did not inspect the prop argument before copying union charger_propval across the user/kernel boundary. Two members of that union are function pointers — status_notification (CHARGER_PROP_STATUS_NOTIFICATION) and online_notification (CHARGER_PROP_ONLINE_NOTIFICATION), declared in include/zephyr/drivers/charger.h — and z_vrfy_charger_set_prop() forwarded the caller-supplied union verbatim to the driver's set_property callback for any property. z_vrfy_charger_get_prop() had the mirror defect and copied the stored kernel callback address back out to user memory. With CONFIG_USERSPACE enabled, any user-mode thread that has been granted a charger device object could call charger_set_prop() with CHARGER_PROP_STATUS_NOTIFICATION or CHARGER_PROP_ONLINE_NOTIFICATION and an arbitrary pointer value. Drivers that implement these properties — drivers/charger/charger_max20335.c, drivers/charger/charger_pf1550.c and drivers/charger/charger_bq2518x.c — store the pointer in device data and later invoke it from their interrupt work handlers, which run in supervisor mode, on any charger state change such as a cable plug/unplug. The result is a control-flow hijack at kernel privilege from an unprivileged thread, defeating the isolation that CONFIG_USERSPACE is meant to provide; the read path additionally disclosed a kernel code address to user mode, and clearing a notifier installed by a supervisor thread let user mode suppress charger notifications. Supervisor-mode callers of charger_set_prop()/charger_get_prop() are unaffected. The fix makes both verifiers reject the two notifier properties outright — including when the supplied callback is NULL, since the notifiers are device state — and adds a BUILD_ASSERT on CHARGER_PROP_COMMON_COUNT so that new properties force a re-review of the union's user-mode safety.
Fix and what to do
No verified fix here yet
Check whether your product and version are affected, then follow the publisher’s advisory to update. A published fix does not mean it has been installed on your systems.
Published CVSS metrics
CVSS 3.1 · 7.8/10
vulnerabilities@zephyrproject.org
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Reported weaknesses : CWE-822